Glass Lined Steel Tank – Glass lining is applied to the interior surface of the steel providing a tough wear resistant lining which minimizes the effects of high temperature hot water.
Designed for 180° F.
Sturdy Steel Jacket – Heavy gauge steel jacket. 2” High Density Foam Insulation – Minimizes heat loss with an R value of 12.5.
Magnesium Anode Rod – for protection and longer service life. Two ¾” Aquastat NPT Fittings – Located in the lower and upper part of the tank.
All Tanks are constructed and Certified – In accordance with ASME IV, Part HLW for 125 PSI (862 kPa).
Five Year Limited Warranty on Steel Tank – Provide warranty
protection against tank failure resulting from defects in materials and workmanship.
Ten Year Limited Warranty on Steel Tank (with double glass lining) – Provide superior warranty protection against tank failure. Double glass lining is not an inventory item, built upon request.
5-Year Limited Tank Warranties/5-Year Limited Warranty on Component Parts
For more information on warranty, please call Solar Skies Mfg., LLC For products installed in USA, Canada and Puerto Rico; some states do not allow limitations on warranties. See complete copy of the warranty included with the heater.
Part #
Nominal Gal. Cap.
Actual Gal. Cap.
Vert. Hight
Horiz Hight
"L"
"D"
Base Clearance
"H"
Dia.
Weight @125#
916-035
193
175
71"
41"
67"
18"
2"
19.5"
34"
438
916-036
229
210
83"
41"
79"
24"
2"
20"
34"
493
916-037
260
240
93"
41"
89"
29"
2"
20"
34"
539
916-038
303
280
107"
41"
103"
36"
2"
20"
34"
603
916-039
340
320
119"
41"
115"
42"
2"
20"
34"
658
916-040
318
285
80"
47"
76"
21"
2"
21"
40"
667
916-041
344
310
86"
47"
82"
24"
2"
21"
40"
710
916-042
375
340
93"
47"
89"
28"
2"
21"
40"
760
916-043
397
360
98"
47"
94"
30"
2"
21"
40"
796
916-044
449
415
110"
47"
106"
36"
2"
21"
40"
881
916-045
502
465
122"
47"
118"
42"
2"
21"
40"
967
916-046
555
515
134"
47"
130"
48"
2"
21"
40"
1053
916-047
486
435
89"
53"
85"
24"
2"
22.5"
46"
917
916-048
504
453
92"
53"
88"
26"
2"
23"
46"
942
916-049
558
505
101"
53"
97"
30"
2"
23"
46"
1017
916-050
630
575
113"
53"
109"
36"
2"
23"
46"
1117
916-051
702
645
125"
53"
121"
42"
2"
23"
46"
1217
916-052
774
720
137"
53"
133"
48"
2"
23"
46"
1317
916-053
846
790
147"
53"
143"
53"
2"
23"
46"
1400
916-054
572
500
81"
59"
77"
18.5"
2"
24"
52"
1176
916-055
658
580
92"
59"
88"
24"
2"
24"
52"
1310
916-056
752
675
104"
59"
100"
30"
2"
24"
52"
1456
916-057
846
765
116"
59"
112"
36"
2"
24"
52"
1602
916-058
940
840
128"
59"
124"
42"
2"
24"
52"
1748
916-059
1128
1040
149"
59"
145"
53"
2"
24"
52"
2003
W-H-196 Test = 7.0 - 8.0 mg/in²
The W-H-196 Test is required for water heaters sold to the U.S. Government. The test consists of exposing the enamel to a boiling (212 F) 4/10% solution of Sodium Bicarbonate for eight (8), eighteen (18) hour cycles. Maximum weight loss after eight cycles is not to exceed 15 mg/in² .
PEI T-21 Spot Acid Test = Class A
PEI T-21 Spot Acid Test is used to determine enamel resistance to acids. The test area is examined for visible effects on the enamel and is graded from Class AA (no sign of etching) to Class D (etched surface).
Impact resistance = Class 4 to 5
The Impact Resistance Test is used to determine the adhesive qualities of enamel to the substrate. The enamel is graded from Class 1 (worst) to Class 5 (best), fractured glass adhering solidly to the impact area. Class 3 is acceptable.
Hi-Pot Test Less than 20
The HYPO Test is a measurement of the continuity of the glass coating (Spark Test). Fifty (50) breakthroughs or fewer are the usual specification for HWT's.